WQDS SS304 Sewage Pumps. Stainless construction. Flanged wastewater duty.

WQ(D)-S is a national-standard-flange submersible sewage-pump family with a stainless-steel precision-cast shell. It is intended for wastewater transfer, aquaculture drainage and selected corrosive or fibrous media after liquid-chemistry, solids and material compatibility have been checked. The catalog distinguishes single-phase WQD configurations from three-phase WQ configurations.

01Rated flow10–180 m³/h
02Rated lift6–60 m
03Motor range0.75–15 kW

ENGINEERING DETAILS

Control, protection and operating limits.

The product introduction is summarized above. This section continues with the functional design, permitted operating conditions and model-code structure.

DESIGN & OPERATION
01

Stainless precision casting

A stainless-steel shell improves corrosion resistance, subject to compatibility of the complete wetted assembly with the actual liquid.

02

Two mechanical-seal groups

The catalog specifies double-end and single-end mechanical seals with fluororubber elements for sealing and corrosion resistance.

03

Motor protection

Class F insulation is specified; models up to 4 kW may be equipped with a thermal protector.

04

Medium-specific options

Cutting devices for fibers and debris, mixing devices for sediment and hot-water motor configurations are quotation-dependent options, not standard on every model.

OPERATING CONDITIONS
  1. 01

    Maximum submersion depth: 5 m; position the pump and lifting arrangement for the actual wet-well operating levels.

  2. 02

    Standard liquid temperature: up to +40 °C. Higher-temperature motor options require explicit configuration review.

  3. 03

    Catalog pH guidance: 304 stainless steel approximately pH 4–10; 316 stainless steel approximately pH 2–13. Chemistry, concentration and all wetted materials require confirmation.

  4. 04

    Rated supply: 50 Hz, 220 V single-phase or 380 V three-phase by model; permitted voltage fluctuation is approximately ±10% of rated value.

  5. 05

    For solids, long fibers or sediment, specify particle size, concentration and whether a cutter or mixer is required before selection.

MODEL CODE50 WQ(D) 10 - 10 - 0.75 S
  1. 0150

    Discharge caliber in millimetres

  2. 02WQ

    Submersible sewage-pump family

  3. 03D

    Single-phase motor designation (omitted for three-phase WQ)

  4. 0410

    Rated flow in m³/h

  5. 0510

    Rated lift in metres

  6. 060.75

    Rated motor power in kW

  7. 07S

    Stainless-steel construction designation

APPLICATION FIT

Is this the right pump family?

Use the application and construction check below before comparing model numbers. Final selection is always made at the actual operating point.

WQDS SS304 Sewage Pumps illustrative installation environment
STAINLESS WASTEWATER DUTY · INSTALLATION VISUALIZATIONMaterial compatibility added to the hydraulic selection.
BEST SUITED TO
01

Wastewater wet wells

Submerged, flanged transfer with chemistry and solids reviewed.

02

Aquaculture drainage

Confirm pH, salinity, suspended solids and stainless grade.

03

Fibrous sewage

Specify the optional cutting device when long fibers and debris are present.

04

Sediment-prone sump

A mixing device may be configured where bottom deposits are expected.

VERIFY BEFORE SELECTION
Liquid chemistryCheck pH, salinity, concentration and all wetted materials
Solids / fibersSpecify particle size, loading and cutter or mixer requirement
Maximum immersion5 m
Liquid temperatureStandard duty up to +40 °C; hot-water version by confirmation
Electrical supply50 Hz; 220 V single-phase or 380 V three-phase by configuration
Flanged outlet50–150 mm caliber in the listed models

MODEL SELECTION

Compare the operating range.

Shortlist by flow and total head first. Motor power, connection and construction are verified after the duty point is known.

Catalog electrical entries identify available 220 V or 380 V configurations, not a dual-voltage motor. Confirm phase, materials and flange dimensions for the ordered model.

ModelRated flowRated liftRated powerVoltageCaliberSynchronous speedOutline mounting dimensions (L/L1/L2/B/H/H1)Pump outlet (D/D0/n-d0/D1)
01 · 220 V or 380 V configurations Supply and stainless grade depend on the confirmed variant.
50WQ(D)10-10-0.75S10 m³/h10 m0.75 kW220/380 V50 mm3000 r/min349/140/246/212/492/110 mmφ50/φ110/4-φ14/φ140
65WQ(D)15-6-0.75S15 m³/h6 m0.75 kW220/380 V65 mm3000 r/min353/140/246/212/492/110 mmφ65/φ130/4-φ14/φ160
50WQ(D)15-10-1.1S15 m³/h10 m1.1 kW220/380 V50 mm3000 r/min353/140/246/212/522/110 mmφ50/φ110/4-φ14/φ140
65WQ(D)25-7-1.1S25 m³/h7 m1.1 kW220/380 V65 mm3000 r/min353/140/246/212/522/110 mmφ65/φ130/4-φ14/φ160
50WQ(D)15-15-1.5S15 m³/h15 m1.5 kW220/380 V50 mm3000 r/min353/140/246/212/522/110 mmφ50/φ110/4-φ14/φ140
65WQ(D)25-10-1.5S25 m³/h10 m1.5 kW220/380 V65 mm3000 r/min353/140/246/212/522/110 mmφ65/φ130/4-φ14/φ160
80WQ(D)40-6-1.5S40 m³/h6 m1.5 kW220/380 V80 mm3000 r/min411/155/261/207/539/119 mmφ80/φ150/4-φ17.5/φ190
50WQ(D)15-20-2.2S15 m³/h20 m2.2 kW220/380 V50 mm3000 r/min369/158/266/217/558/118 mmφ50/φ110/4-φ14/φ140
65WQ(D)25-15-2.2S25 m³/h15 m2.2 kW220/380 V65 mm3000 r/min385/161/267/220/557/119 mmφ65/φ130/4-φ14/φ160
80WQ(D)40-9-2.2S40 m³/h9 m2.2 kW220/380 V80 mm3000 r/min431/169/283/228/564/122 mmφ80/φ150/4-φ17.5/φ190
100WQ(D)50-7-2.2S50 m³/h7 m2.2 kW220/380 V100 mm3000 r/min480/180/302/244/579/129 mmφ100/φ170/4-φ17.5/φ210
02 · 380 V three-phase models Supply and stainless grade depend on the confirmed variant.
50WQ15-25-3S15 m³/h25 m3 kW380 V50 mm3000 r/min389/168/286/236/575/117 mmφ50/φ110/4-φ14/φ140
65WQ25-20-3S25 m³/h20 m3 kW380 V65 mm3000 r/min406/169/288/238/580/119 mmφ65/φ130/4-φ14/φ160
80WQ40-15-3S40 m³/h15 m3 kW380 V80 mm3000 r/min448/176/300/255/588/121 mmφ80/φ150/4-φ17.5/φ190
100WQ50-10-3S50 m³/h10 m3 kW380 V100 mm3000 r/min502/191/324/265/605/129 mmφ100/φ170/4-φ17.5/φ210
50WQ15-32-4S15 m³/h32 m4 kW380 V50 mm3000 r/min389/168/286/236/600/117 mmφ50/φ110/4-φ14/φ140
65WQ25-25-4S25 m³/h25 m4 kW380 V65 mm3000 r/min406/169/288/238/605/119 mmφ65/φ130/4-φ14/φ160
80WQ40-18-4S40 m³/h18 m4 kW380 V80 mm3000 r/min448/176/300/255/613/121 mmφ80/φ150/4-φ17.5/φ190
100WQ50-15-4S50 m³/h15 m4 kW380 V100 mm3000 r/min502/191/324/266/630/129 mmφ100/φ170/4-φ17.5/φ210
50WQ20-32-5.5S20 m³/h32 m5.5 kW380 V50 mm3000 r/min425/189/322/266/689/125 mmφ50/φ110/4-φ14/φ140
65WQ30-25-5.5S30 m³/h25 m5.5 kW380 V65 mm3000 r/min440/189/322/284/691/126 mmφ65/φ130/4-φ14/φ160
80WQ50-18-5.5S50 m³/h18 m5.5 kW380 V80 mm3000 r/min490/200/342/285/714/139 mmφ80/φ150/4-φ17.5/φ190
100WQ80-10-5.5S80 m³/h10 m5.5 kW380 V100 mm3000 r/min528/202/350/295/722/141 mmφ100/φ170/4-φ17.5/φ210
150WQ100-7-5.5S100 m³/h7 m5.5 kW380 V150 mm3000 r/min608/225/379/308/733/150 mmφ150/φ225/8-φ17.5/φ265
50WQ20-40-7.5S20 m³/h40 m7.5 kW380 V50 mm3000 r/min437/189/334/289/722/158 mmφ50/φ110/4-φ14/φ140
65WQ30-32-7.5S30 m³/h32 m7.5 kW380 V65 mm3000 r/min462/199/344/298/735/166 mmφ65/φ130/4-φ14/φ160
80WQ45-22-7.5S45 m³/h22 m7.5 kW380 V80 mm3000 r/min493/200/345/288/747/172 mmφ80/φ150/4-φ17.5/φ190
100WQ80-15-7.5S80 m³/h15 m7.5 kW380 V100 mm3000 r/min528/202/350/295/755/174 mmφ100/φ170/4-φ17.5/φ210
150WQ100-10-7.5S100 m³/h10 m7.5 kW380 V150 mm3000 r/min608/225/379/308/772/183 mmφ150/φ225/8-φ17.5/φ265
65WQ30-50-11S30 m³/h50 m11 kW380 V65 mm3000 r/min480/218/362/288/927/180 mmφ65/φ130/4-φ14/φ160
80WQ45-42-11S45 m³/h42 m11 kW380 V80 mm3000 r/min512/220/364/288/933/186 mmφ80/φ150/4-φ17.5/φ190
100WQ100-20-11S100 m³/h20 m11 kW380 V100 mm3000 r/min528/202/349/295/924/179 mmφ100/φ170/4-φ17.5/φ210
150WQ180-11-11S180 m³/h11 m11 kW380 V150 mm3000 r/min608/224/379/308/935/183 mmφ150/φ225/8-φ17.5/φ265
65WQ30-60-15S30 m³/h60 m15 kW380 V65 mm3000 r/min480/218/362/288/927/180 mmφ65/φ130/4-φ14/φ160
80WQ45-52-15S45 m³/h52 m15 kW380 V80 mm3000 r/min512/220/364/288/933/186 mmφ80/φ150/4-φ17.5/φ190
100WQ100-25-15S100 m³/h25 m15 kW380 V100 mm3000 r/min528/202/349/295/924/179 mmφ100/φ170/4-φ17.5/φ210
150WQ180-15-15S180 m³/h15 m15 kW380 V150 mm3000 r/min608/224/379/308/935/183 mmφ150/φ225/8-φ17.5/φ265
Catalog reference · LBA PRO WQ(D)-S technical sheet, product and conditions page 08; WQ(D) technical parameters and 21-part drawing page 09Need help choosing? Send the duty point →

TECHNICAL LIBRARY

Explore the pump construction.

Switch between the complete pump and its construction view, then use the numbered parts index for identification.

01
Complete / exploded viewOriginal LBA PRO WQ(D)-S exploded drawing · 21 numbered components
WQDS SS304 Sewage Pumps complete assembled pump
Complete pump
WQDS SS304 Sewage Pumps exploded construction view with 21 indexed components
Original LBA PRO WQ(D)-S exploded drawing · 21 numbered components

The expanded state retains the supplier's numbered drawing and the right-side index transcribes all 21 labels. The complete state shows the assembled WQDS pump. Confirm the exact configuration and service part numbers before ordering.

02
Parts indexNumbered construction reference
  1. 01ChassisStructure
  2. 02Pump bodyHydraulic
  3. 03ImpellerHydraulic
  4. 04Mechanical sealSealing
  5. 05Oil chamberSealing
  6. 06O-ring sealSealing
  7. 07EnclosureMotor
  8. 08Deep-groove ball bearingDrive
  9. 09Top chockDrive
  10. 10Top coverEnclosure
  11. 11Lifting ringsHandling
  12. 12Electric cableElectrical
  13. 13O-ring sealSealing
  14. 14Deep-groove ball bearingDrive
  15. 15RotorMotor
  16. 16Stator coilMotor
  17. 17Bottom chockDrive
  18. 18Mechanical sealSealing
  19. 19O-ring sealSealing
  20. 20Outlet elbowHydraulic
  21. 21Flange cushionHydraulic
03
Available technical contentNo unverified performance curve shown
  • Complete model performance table
  • Operating conditions
  • WQDS model-code guide
  • 21-part construction index
Open pump catalog ↗

REQUEST SELECTION

Send the duty point.
Receive a model shortlist.

Motor power alone is not enough to select a pump reliably.

  1. 01Rated flow and total dynamic head
  2. 02Liquid pH, chemistry and required stainless grade
  3. 03Solids, long fibers and cutter/mixer requirement
  4. 04Flange caliber, voltage and wet-well installation