Technical selection, cross-reference and global export supportSend a model or application
Home/Industrial Pumps/QJD deep-well pumps
Actual LBA PRO Y80QJD oil-filled deep-well pump with black discharge head, perforated intake and stainless motor
ACTUAL PRODUCT PHOTOY80QJD

Y80QJD + Y90QJD · OIL-FILLED

Deep-well water supply, matched to the bore and duty point.

QJD pumps pair a slim multistage hydraulic section with an oil-filled motor. Y80 covers 2 and 3 m³/h rated-flow families; Y90 extends the choice from 2 to 15 m³/h. Select by the actual flow, total head and well clearance.

01Y80QJD2 / 3 m³/h
02Y90QJD2–15 m³/h
03Listed supply220 V

PRODUCT INFORMATION

Built for submerged, multistage lifting.

The right series is determined by the well and operating point—not motor power alone.

01 · WATER ENTRY

Screened intake

Water enters through the perforated band and passes through the hydraulic stages.

02 · HYDRAULICS

Head from repeated stages

Impeller and diffuser stages raise pressure. Use the Q–H curve to check the head available at required flow.

03 · DRIVE

Oil-filled motor

The submerged cylindrical motor drives the stage stack. Confirm voltage, cable and protection for the ordered model.

04 · INSTALLATION

Bore clearance matters

Check the pump's actual outside diameter against the well casing, including the cable and installation tolerance.

APPLICATION FIT

Start with the well, then the curve.

Dynamic water level, pipe losses and required outlet pressure define the total head. Well diameter determines which pump can be installed safely.

Cutaway visualization of a slim QJD deep-well pump submerged inside the borehole casing, with riser pipe and electrical cable leading to the wellhead
DEEP-WELL INSTALLATION · VISUALIZATIONPump below the water level, inside the casing.
TYPICAL DUTIES
01

Groundwater supply

Use the required outlet flow and drawdown level to calculate the duty point.

02

Farm irrigation

Match the operating flow to the irrigation zone and its pressure losses.

03

Livestock watering

Confirm the daily demand and storage or trough-filling schedule.

04

Long-head water transfer

Include lift, delivery-pipe friction and outlet pressure in total head.

CHECK BEFORE SELECTION
Well geometryCasing diameter, depth and pump setting level
HydraulicsFlow, dynamic water level, discharge elevation, pressure and friction loss
Water conditionTemperature, sand content and intended use
Electrical supplyVoltage, phase, frequency, motor protection and control method

MODEL SELECTION

Compare Y80 and Y90 at the real duty point.

Choose the flow family first. Then compare model head, connection and power, with Q–H data and construction below.

MODEL RANGE

Y90QJD specifications

100 mm, 220 V oil-filled multistage borehole pumps with six rated-flow families from 2 to 15 m³/h.

27models to compare
ModelRated flowRated headMaximum headPowerOutlet
Y90QJD2-60/11-0.752 m³/h60 m72 m0.75 kW1"
Y90QJD2-90/16-1.12 m³/h90 m104 m1.1 kW1"
Y90QJD2-125/20-1.52 m³/h125 m135 m1.5 kW1"
Y90QJD2-140/23-1.82 m³/h140 m150 m1.8 kW1"
Y90QJD2-160/26-2.22 m³/h160 m200 m2.2 kW1"
Y90QJD4-45/9-0.754 m³/h45 m54 m0.75 kW1.5"
Y90QJD4-58/12-1.14 m³/h58 m71 m1.1 kW1.5"
Y90QJD4-77/16-1.54 m³/h77 m96 m1.5 kW1.5"
Y90QJD4-85/18-1.84 m³/h85 m107 m1.8 kW1.5"
Y90QJD4-100/20-2.24 m³/h100 m119 m2.2 kW1.5"
Y90QJD6-30/6-0.756 m³/h30 m37 m0.75 kW1.5"
Y90QJD6-40/8-1.16 m³/h40 m50 m1.1 kW1.5"
Y90QJD6-50/10-1.56 m³/h50 m62 m1.5 kW1.5"
Y90QJD6-56/11-1.86 m³/h56 m68 m1.8 kW1.5"
Y90QJD6-70/13-2.26 m³/h70 m81 m2.2 kW1.5"
Y90QJD8-18/4-0.758 m³/h18 m25 m0.75 kW2"
Y90QJD8-27/6-1.18 m³/h27 m38 m1.1 kW2"
Y90QJD8-38/8-1.58 m³/h38 m50 m1.5 kW2"
Y90QJD8-42/9-1.88 m³/h42 m55 m1.8 kW2"
Y90QJD8-55/12-2.28 m³/h55 m75 m2.2 kW2"
Y90QJD10-22/5-1.110 m³/h22 m30 m1.1 kW2"
Y90QJD10-30/7-1.510 m³/h30 m40 m1.5 kW2"
Y90QJD10-35/8-1.810 m³/h35 m45 m1.8 kW2"
Y90QJD10-40/10-2.210 m³/h40 m50 m2.2 kW2"
Y90QJD15-21/6-1.515 m³/h21 m35 m1.5 kW2.5"
Y90QJD15-25/7-1.815 m³/h25 m40 m1.8 kW2.5"
Y90QJD15-32/9-2.215 m³/h32 m50 m2.2 kW2.5"

Check the ordered model's dimensions and electrical data before installation. For Y80, one catalog shows Ø88 mm while a later model list shows Ø92 mm; confirm the actual outside diameter against the well casing.

SELECTED HYDRAULIC FAMILY

Y90QJD · 2 m³/h family

FLOW RANGE0–6 m³/h
HEAD ENVELOPE0–200 m
Y90QJD 2 m³/h family flow and head curvesCatalog flow and head values are marked with circular points and joined by shape-preserving smooth curves. Select a model below to emphasize its curve.0501001502000123456FLOW Q (m³/h)HEAD H (m)
ACTIVE CURVE

Y90QJD2-160/26-2.2

Every circular marker reproduces a value from the supplied Y90QJD technical table. The connecting line uses shape-preserving interpolation and does not create additional measurements.

Catalog points for Y90QJD2-160/26-2.2
Flow Q0 m³/h1 m³/h2 m³/h3 m³/h4 m³/h5 m³/h6 m³/h
Head H200 m181 m160 m138 m112 m85 m51 m
PRODUCT CONSTRUCTION

See the QJD assembly, complete and expanded.

Switch views, then select a structural group to understand its role. The exact number of stages and service components depends on the ordered model.

Illustrative 3D exploded reconstruction of a slender QJD-type multistage deep-well pump with outlet, hydraulic stages, intake, motor and cable
Expanded QJD-type structure · visual reconstruction based on the supplied product photo
03 / 06 · Multistage hydraulics

Impellers and diffusers

Repeated stages add head; the stage count changes with the selected model.

The expanded image is a new visual reconstruction, not original-factory CAD or a verified spare-parts drawing. Do not use its visual details as orderable part numbers.

COMMON QUESTIONS

Before specifying a QJD pump

What must be confirmed before quotation?

Provide bore diameter, static and dynamic levels, required flow and pressure, pipe details and power supply.

Is rated head the same as the operating head?

No. Selection should use the pump curve at the required operating flow and calculated total dynamic head.

REQUEST SELECTION

Send the duty point.
Receive a model shortlist.

Include well casing diameter, dynamic water level and power supply.

  1. 01Well geometry
  2. 02Hydraulics
  3. 03Water condition
  4. 04Electrical supply
Send project data →