Solar borehole irrigation
Off-grid groundwater lifting with the photovoltaic array and controller selected for the duty point.

Solar Deep-well Pump Systems
Photovoltaic 4-inch shielded deep-well pumps for off-grid water supply, livestock watering and irrigation.
APPLICATION FIT
Use the application and construction check below before comparing model numbers. Final selection is always made at the actual operating point.

Off-grid groundwater lifting with the photovoltaic array and controller selected for the duty point.
Pump during available solar hours and use water storage to cover demand outside pumping periods.
Match daily volume, drawdown, lift and seasonal solar resource before sizing the array.
Use where grid power is unavailable, subject to water quality and installation review.
MODEL SELECTION
Shortlist by flow and total head first. Motor power, connection and construction are verified after the duty point is known.
| Model | DC voltage | Rated power | Catalog flow span | Head at Q=0 | Head at 3.6 m³/h | Outlet | Outside diameter |
|---|---|---|---|---|---|---|---|
| 4PTS5-33/3-0.45/24 | 24 V | 0.45 kW | 0–3.6 m³/h | 33 m | 14 m | 1¼" | 98 mm |
| 4PTS5-51/4-0.55/48 | 48 V | 0.55 kW | 0–3.6 m³/h | 51 m | 19 m | 1¼" | 98 mm |
| 4PTS5-62/5-0.75/48 | 48 V | 0.75 kW | 0–3.6 m³/h | 62 m | 21 m | 1¼" | 98 mm |
| 4PTS5-62/5-0.75/72 | 72 V | 0.75 kW | 0–3.6 m³/h | 62 m | 21 m | 1¼" | 98 mm |
| 4PTS5-93/7-1.1/110 | 110 V | 1.1 kW | 0–3.6 m³/h | 93 m | 39 m | 1¼" | 98 mm |
| 4PTS5-146/13-1.3/110 | 110 V | 1.3 kW | 0–3.6 m³/h | 146 m | 61 m | 1¼" | 98 mm |
| 4PTS5-203/18-1.5/110 | 110 V | 1.5 kW | 0–3.6 m³/h | 203 m | 85 m | 1¼" | 98 mm |
Q–H PERFORMANCE
Redrawn from all six flow columns in the supplied PTS catalog table. Select an exact voltage and power model to inspect every published point.
The circular markers reproduce the six values in the supplied PTS catalog table. The line between those points is a smooth visual interpolation, not an additional measurement.
| Flow Q | 0 m³/h | 1 m³/h | 2 m³/h | 2.4 m³/h | 3 m³/h | 3.6 m³/h |
|---|---|---|---|---|---|---|
| Head H | 203 m | 170 m | 138 m | 122 m | 105 m | 85 m |
TECHNICAL LIBRARY
Follow the complete operating path from photovoltaic input and MPPT control to the submerged pump, rising main, storage tank and irrigation outlet.

The animation uses the supplied product family as its hardware reference. Final array size, controller, cable and pipework must be matched to the selected voltage and duty point.

PV modules produce DC power during usable sunlight.
The controller regulates voltage and protects the pump system.
The submerged PTS pump converts electrical input into water flow and head.
The rising main fills a tank so stored water can serve irrigation after pumping slows.
This is an operating-principle visualization, not a site-specific installation drawing. Confirm the dynamic water level, total dynamic head, daily volume, solar resource, controller limits and cable voltage drop before configuration.
REQUEST SELECTION
Motor power alone is not enough to select a pump reliably.